ESCR 2016 / P-0024 |
![]() |
Quantitative myocardial perfusion measured before and after invasive treatment using advanced CT-technology |
Congress: | ESCR 2016 |
Poster No.: | P-0024 |
Type: | Scientific Poster |
Keywords: | Cardiac, CT-Quantitative, Diagnostic procedure, Ischaemia / Infarction |
Authors: | T. Rienmüller1, C. Baumgartner1, V. Makarenko2, V. Bereznitskiy2, I. Rychina2, P. Ourednicek3, R. Rienmüller1; 1Graz/AT, 2Moscow/RU, 3Brno/CZ |
References
Baumgartner C. Messung der cerebralen Durchblutung mittels Elektronenstrahl- Computertomographie. PhD thesis, TUGraz, 1998.
Chan A. A. and Sarah J. Nelson. Simplified gamma-variate fitting of perfusion curves. Biomedical Imaging: Nano to Macro, 2004. IEEE International Symposium on, 2:1067 – 1070, 2004.
Janssens G., L. Jacques, J. Orban de Xivry, X. Geets, and B. Macq. Diffeomorphic registration of images with variable contrast enhancement. International Journal of Biomedical Imaging, 2011 (Article ID 891585):16 pages, 2011.
Miles K.A. Measurement of tissue perfusion by dynamic computed tomography. British Journal of Radiology, 64(761):409–412, May 1991.
Osbakken M., A. A. Bove, and J. F. Spann. Left ventricular function in chronic aortic regurgitation with reference to end-systolic pressure, volume and stress relations. The American Journal of Cardiology, 47(2):193–198, 1981.
Rienmüller T., M. Handler, P. Ourednicek, V. Makarenko, L. Bockeria, I. M. Krestinich, S. T. Zhorzholiani, and R. Rienmüller. Contrast agent concentration of 180-210 mgI/ml allows for quantitative estimation of myocardial perfusion in dogs. In EPOS at ECR 2013, 2013.
Uren N.G., J. A. Melin, B. De Bruyne, W. Wijns, T. Baudhuin, and P. G. Camici. Relation between myocardial bloodflow and the severity of coronary artery stenosis. N Engl J Med, 330:1782–1788, 1994.
Thematically related posters
ESCR 2016 / P-0040

Quantification of myocardial perfusion using dynamic CT perfusion analysis on third generation dual source CT in an ex-vivo porcine heart model